食品科学

• 分析检测 • 上一篇    下一篇

动态反应池-电感耦合等离子体质谱法测定酒中的镉、汞、铅和铬

燕 娜,赵生国,高芸芸   

  1. 甘肃出入境检验检疫局检验检疫综合技术中心,甘肃 兰州 730010
  • 出版日期:2013-06-25 发布日期:2013-06-17

Determination of Cadmium, Mercury, Lead and Chromium in Alcoholic Drinks by Inductively Coupled Plasma-Mass Spectrometry with Dynamic Reaction Cell

YAN Na,ZHAO Sheng-guo,GAO Yun-yun   

  1. Inspection and Quarantine Technology Center, Gansu Entry-Exit Inspection and Quarantine Bureau, Lanzhou 730010, China
  • Online:2013-06-25 Published:2013-06-17

摘要:

酒样经稀硝酸消解,动态反应池-电感耦合等离子体质谱法测定消解液中的镉、汞、铅和铬。通过优化硝酸溶液体积分数、消解温度、消解时间和样品稀释倍数,确定这4个参数的最优值分别为50%、95℃、1h和5倍。此外,在降低基质干扰、消除汞吸附、优化仪器条件等方面进行讨论。利用建立的方法测定红葡萄酒、白葡萄酒、白酒、啤酒和黄酒中的镉、汞、铅和铬含量。酒样中镉、汞、铅和铬的检出限分别为0.01、0.01、0.08、0.03μg/L,回收率在89.6%~106.5%之间。此方法高效、灵敏、准确,适合大批量样品的同时处理。

关键词: 动态反应池, 电感耦合等离子体质谱, 镉, 汞, 铅, 铬,

Abstract:

Digestion with dillute nitric acid followed by inductively coupled plasma-mass spectrometry (ICP-MS) with
dynamic reaction cell (DRC) was used to determine the levels of cadmium, mercury, lead and chromium in alcoholic
drinks. The optimal levels of nitric acid concentration (volume fraction), temperature, time and sample dilution factor for
the digestion process were found to be 50%, 95 ℃, 1 h and 5, respectively. Further investigations were also carried out
into reduction of matrix interferences, eliminiation of mercury adsorption and optimization of instrumental conditions. The
contents of cadmium, mercury, lead, chromium in red wine, white wine, liquor, beer and rice wine was determined by the
presented method. The limits of detection for cadmium, mercury, lead, chromium were found to be 0.01, 0.01, 0.08 μg/L,
and 0.03 μg/L, respectively. The precision of this method was in the range of 0.48% to 12.87% (RSD), and recovery rates
ranged from 89.6% to 106.5%. This method was efficient, sensitive, accurate and suitable for large-scale determination.

Key words: dynamic reaction cell, inductively coupled plasma-mass spectrometry (ICP-MS), cadmium, mercury, lead, chromium, alcoholic drinks