食品科学

• 分析检测 • 上一篇    下一篇

冷却鸡肉肉色色差计评定方法标准化

魏心如,李伟明,闫海鹏,韩敏义,徐幸莲*,周光宏   

  1. 南京农业大学 农业部畜产品加工重点实验室,江苏 南京 210095
  • 出版日期:2014-12-25 发布日期:2014-12-29
  • 通讯作者: 徐幸莲
  • 基金资助:

    国家现代农业(鸡肉)产业技术体系建设专项(CARS-42-5);“十二五”国家科技支撑计划项目(BAD28B01-03)

Standardization of Color Measurement of Chilled Chicken Using Colorimeter

WEI Xin-ru, LI Wei-ming, YAN Hai-peng, HAN Min-yi, XU Xing-lian*, ZHOU Guang-hong   

  1. Key Laboratory of Animal Product Processing, Ministry of Agriculture, Nanjing Agricultural University, Nanjing 210095, China
  • Online:2014-12-25 Published:2014-12-29
  • Contact: XU Xing-lian

摘要:

研究不同测定条件和肉样预处理方法对冷却鸡肉肉色色差计评定方法的影响,具体探讨表面位置、取点位置、光照强度(60、200、600 lx)、背景色(红、白、黑)以及发色时间(15、30、45、60 min)和发色温度(0~4、10、25 ℃)对肉色测定的影响。结果表明:不同的表面位置和取点位置对鸡肉肉色的测定结果影
响显著(P<0.05);光照强度对肉色测定结果的影响不显著;背景色对最薄部位的肉色测定结果有显著性影响(P<0.05),而对较厚部位的结果影响不显著;在10、25 ℃条件下,发色时间对肉色的测定结果没有影响,而在0~4 ℃条件下,L*值随发色时间的延长显著性降低,与0~4 ℃本身的冷库条件有关;3 种温度环境条件下在30 min发色测得的肉色的变异系数最小。综合各方面因素考虑,选取测定位置为鸡胸肉靠近肋骨一侧表面以及鸡胸肉表面中间1/3面积范围内,置于稳定的室温环境(一般为25 ℃)作为发色温度,发色时间选择30 min,外界光照强度和背景色分别选择常用的600 lx和白色。

关键词: 鸡胸肉, 色差计, 肉色, 评定

Abstract:

The effects of different measurement conditions and pretreatment methods on the measurement of chilled chicken
color using colorimeter were studied. The experimental parameters investigated included measurement position (dorsal and
ventral), illumination intensity (60, 200 and 600 lx), background color (red, white and black), blooming time (15, 30, 45
and 60 min) and blooming temperature (0–4, 10 and 25 ℃). The results showed that measurement position had a significant
effect on meat color (P < 0.05). Light intensity did not affect the results. Background had a significant effect on only the thin
position (P < 0.05), while it had no significant effect on the thick position. At both 10 ℃ and 25 ℃, blooming time had no
effect on breast color, while the L* value significantly decreased with increasing blooming time at 0–4 ℃ (P < 0.05). This
phenomenon had some relation to the conditions of refrigeration. The smallest coefficient of variation (CV) was obtained for
color data from 30 min blooming at all temperatures. In conclusion, chicken breast close to the ribs and the one-third middle
part of the whole breast were suitable for color measurement. Blooming was performed for 30 min at stable normal indoor
temperature (25 ℃) and the best background color and illumination intensity were white and 600 lx, respectively.

Key words: chicken breast, meat color, colorimeter, assessment

中图分类号: