食品科学

• 基础研究 • 上一篇    下一篇

超声局部效应对咖啡酸稳定性及抗氧化性的影响

朱攀攀,马亚琴*,窦华亭*,韩 智,李 申   

  1. 西南大学柑桔研究所,国家柑桔工程技术研究中心,重庆 400712
  • 出版日期:2015-12-15 发布日期:2015-12-24

Effect of Local Ultrasound on Stability and Antioxidant Capacity of Caffeic Acid in a Model System

ZHU Panpan, MA Yaqin*, DOU Huating*, HAN Zhi, LI Shen   

  1. National Citrus Engineering Research Center, Citrus Research Institute, Southwest University, Chongqing 400712, China
  • Online:2015-12-15 Published:2015-12-24

摘要:

将超声区域定位划分成高低两个超声辐射面和5 个不同超声位置(P1、P2、P3、P4、P5),对比研究低超声辐射面与高超声辐射面、超声位置、提取溶剂对咖啡酸稳定性及其抗氧化性的影响。结果表明,低超声辐射面能造成咖啡酸显著降解(P<0.05);高超声辐射面、超声能量对咖啡酸稳定性的影响不显著。溶剂类型是影响咖啡酸稳定性的主要因素之一,其中体积分数80%乙醇是咖啡酸理想的提取溶剂。超声槽不同位置上,超声能量的分布是不均一和动态变化的,咖啡酸在P4或P5位置时降解较为显著(P<0.05)。此外,超声处理同样能显著影响咖啡酸的抗氧化性,1,1-二苯基-2-三硝基苯肼(1,1-diphenyl-2-picrylhydrazyl,DPPH)法、铁离子还原力(ferricreducing antioxidant potential assay,FRAP)法及2,2’-联氮-二(3-乙基-苯并噻唑-6-磺酸)二铵盐(2,2’-amino-di)3-ethyl-benzothiazoline 6-sulphonic acid) ammonium salt,ABTS)法3 种方法测定的咖啡酸抗氧化性的变化规律存在一定差异性。DPPH法与FRAP法同时得到P5位置是影响咖啡酸抗氧化性最显著的位置,该位置咖啡酸降解产物的抗氧化性高于咖啡酸自身的。不同超声辐射面上,ABTS法测定咖啡酸的抗氧化性与其含量成正相关,而DPPH自由基清除能力与其含量成负相关。以上表明低超声辐射面,有效的超声能量能显著影响咖啡酸的稳定性和增加其抗氧化性。

关键词: 超声辐射面, 超声波位置, 咖啡酸, 抗氧化

Abstract:

The space of ultrasonic bath was divided according to height and position into high and low ultrasonic irradiation
surface each with five sections such as P1, P2, P3, P4 and P5. The effects of ultrasonic-assisted extraction parameters
including solvent type and locally ultrasonic positions on the stability and antioxidant capacity of caffeic acid under different
ultrasonic irradiation surfaces (at 6 cm and 14 cm high from the bottom) were comparatively analyzed in the present study.
The results showed that caffeic acid was markedly degraded in low irradiation surface (P < 0.05). However, ultrasonic
energy had no significant impact on the stability of caffeic acid in high irradiation surface. The type of solvent was one of
the key factors in determining the stability of caffeic acid and 80% ethanol was the optimal solvent. In the meantime, the
ultrasonic energy distribution was uneven and dynamic in the local positions, and the content of caffeic acid was decreased
significantly in P4 or P5 of ultrasonic bath (P < 0.05). Moreover, the antioxidant activities of caffeic acid as determined by
DPPH, FRAP and ABTS methods exhibited a big difference. Simultaneously, the position of P5 greatly affected antioxidant
activity of caffeic acid evaluated by DPPH and FRAP methods, and of its degraded products had much higher antioxidant
activity. Additionally, antioxidant capacity of caffeic acid as determined by ABTS method was positively correlated with
its content, but DPPH free radical scavenging capacity had a negative correlation. These findings indicated that appropriate
ultrasonic energy could change greatly the stability of caffeic acid and simultaneously enhance its antioxidant capacity in
low irradiation surface.

Key words: ultrasonic irradiation surface, locally ultrasonic position, caffeic acid, antioxidant capacity

中图分类号: