食品科学

• 安全检测 • 上一篇    下一篇

基于宽谱特异性抗体的β2-激动剂多残留电化学免疫传感器的研制

任鹏飞1,邵科峰1,张 洁1,张红琳2,赵 波1,*   

  1. 1.江苏省生物医药功能材料协同创新中心,江苏省生物功能材料重点实验室,南京师范大学化学与材料科学学院,江苏 南京 210023;2.南京晓庄学院食品科学学院,江苏 南京 211171
  • 出版日期:2016-04-25 发布日期:2016-04-13

Development of A Multi-Residue Electrochemical Immunoassay Based on Broad-Spectrum Specific Antibody for Determination of β2-Agonists

REN Pengfei1, SHAO Kefeng1, ZHANG Jie1, ZHANG Honglin2, ZHAO Bo1,*   

  1. 1. Jiangsu Collaborative Innovation Center of Biomedical Functional Material, Jiangsu Key Laboratory of Biofunctional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China;
    2. College of Food Science, Nanjing Xiaozhuang University, Nanjing 211171, China
  • Online:2016-04-25 Published:2016-04-13

摘要:

制备了沙丁胺醇-莱克多巴胺-牛血清蛋白偶联物,并通过动物免疫获得了抗沙丁胺醇-莱克多巴胺-牛血清蛋白宽谱特异性抗体,同时制备了石墨烯-壳聚糖/沙丁胺醇修饰的电化学免疫传感器,并采用循环伏安法和交流阻抗法对电极的电化学性质进行研究。采用间接竞争法进行了克伦特罗、沙丁胺醇和特布他林3 种β2-激动剂的同时检测,检出限依次为0.2、0.3 ng/mL和0.3 ng/mL,线性范围依次为50~7 000、1~1 500 ng/mL和100~6 000 ng/mL。将传感器应用于猪瘦肉、猪脂肪和猪肝3 种实际样品中克伦特罗的加标检测,回收率为84.7%~106%。实现了β2-激动剂的高灵敏多残留免疫检测。

关键词: 宽谱特异性抗体, &beta, 2-激动剂, 多残留, 电化学免疫传感器

Abstract:

Salbutamol-ractopamine-bovine serum albumin conjugate (SAL-RAC-BSA) was prepared and served as
immunogen to obtain a broad-spectrum specific antibody (anti-SAL-RAC-BSA Abs) through immunization of rabbits.
Electrochemical immunosensor modified with reduced graphene oxide-chitosan composite and SAL was constructed and
its electrochemical behavior was studied by cyclic voltammetry and electrochemical impedance spectroscopy. Indirect
competitive electrochemical immunoassay was carried out for the simultaneous determination of three β2-agonis, including
clenbuterol (CL), salbutamol (SAL) and terbutaline (TB). The proposed method indicated a linearity in the range from 50 to
7 000 ng/mL, 1 to 1 500 ng/mL and 100 to 6 000 ng/mL for CL, SAL and TB, respectively, and the limits of detection were
0.2, 0.3 and 0.3 ng/mL, respectively. The recovery rates of clenbuterol in spiked pork, fat and liver samples ranged from
84.7% to 106%. In summary, a sensitive, rapid and simple electrochemical immunoassay was successfully developed for the
determination of three β2-agonists.

Key words: broad-spectrum specific antibodies, β2-agonists, multi-residue, electrochemical immunosensor

中图分类号: