食品科学 ›› 2016, Vol. 37 ›› Issue (20): 113-119.doi: 10.7506/spkx1002-6630-201620019

• 安全检测 • 上一篇    下一篇

基于磁性免疫传感器的牛乳中四环素残留检测方法的构建

康怀彬,马红燕,李 芳,徐宝成,罗登林,张瑞华,邹良亮   

  1. 1.河南科技大学食品与生物工程学院,河南 洛阳 471003;2.河南省食品原料工程技术研究中心,河南 洛阳 471003
  • 收稿日期:2016-10-27 修回日期:2016-10-27 出版日期:2016-10-25 发布日期:2016-12-01
  • 基金资助:

    国家自然科学基金青年科学基金项目(31501563);洛阳市畜牧局项目(2518);
    河南科技大学校级创新团队项目(2015XTD007)

Establishment of Magnetic Bead-Based Immunosensor for the Detection of Tetracycline Residues in Milk

KANG Huaibin, MA Hongyan, LI Fang, XU Baocheng, LUO Denglin, ZHANG Ruihua, ZOU Liangliang   

  1. 1. College of Food and Bioengineering, Henan University of Science and Technology, Luoyang 471003, China;
    2. Henan Engineering Research Center of Food Material, Luoyang 471003, China
  • Received:2016-10-27 Revised:2016-10-27 Online:2016-10-25 Published:2016-12-01

摘要:

建立一种高灵敏磁性光学免疫传感检测方法,可用于生鲜乳中四环素残留的快速检测。方法的检出限为0.03 ng/mL,定量限为0.20 ng/mL;四环素质量浓度在0.25~32 ng/mL时,荧光信号值与质量浓度之间具有良好的线性关系,其回归方程决定系数(R2)为0.995 9;本方法准确度高,四环素不同添加水平条件下的回收率在82.6%~97.0%之间;该方法具有良好的重复性,测定结果的日内精密度和日间精密度均在5.0%以内;本方法与高效液相色谱-串联紫外检测结果高度吻合。

关键词: 磁珠, 免疫反应, 荧光检测, 四环素, 生鲜乳

Abstract:

A highly sensitive and rapid immunofluorescence assay for the detection of tetracycline residues in raw milk
based on magnetic beads was developed. The limit of detection (LOD) and limit of quantification (LOQ) of this method were
0.03 and 0.20 ng/mL, respectively. The fluorescence intensity was linear with the concentration of tetracycline in the range
of 0.25 to 32 ng/mL with a coefficient of determination of 0.995 9 (R2 = 0.995 9). The recoveries of TC spiked at different
concentrations were between 82.6% and 97.0%, indicating that the method is accurate. Furthermore, precision, calculated as
relative standard deviation (RSD), was below 5.0% for intra-day and inter-day determinations, indicating good repeatability of the
method. The results of tetracycline residues in raw milk determined by this method and HPLC-UV were highly consistent.

中图分类号: