摘要: 目的:建立高效液相色谱-四极杆串联质谱仪(LC-MS/MS)同时测定猪肝脏中阿维菌素(AVM)和伊维菌素(IVM)的残留量。方法:猪肝样品均质后用乙腈提取,碱性氧化铝固相萃取柱(SPE)净化,采用串联质谱电喷雾电离ESI(+),多反应监测模式(MRM)检测,以保留时间和子离子比定性,外标法定量。结果:方法检出限(LOD)均为2.0μg/kg,定量限(LOQ)为5.0μg/L,两种药物的线性范围均为5~100μg/L,相关系数均为0.9999。添加水平在2~20μg/kg范围内,阿维菌素和伊维菌素的平均回收率分别为77.0%~83.3%和76.9%~79.8%之间,相对标准偏差(RSD)分别小于12.1%和13.0%。结论:方法操作简单,灵敏准确,可满足当前国内外该产品中此类药物的检测要求。

关键词: 猪肝, 阿维菌素, 伊维菌素, 高效液相色谱-串联质谱

Abstract: Objective: To establish a method for the simultaneous determination of avermectin and ivermectin residues in pork liver using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methods: Avermectin and ivermectin residues were extracted with acetonitrile, cleaned up on a solid phase extraction (SPE) column containing alkaline aluminum oxide, separated on a C8 column, detected by tandem mass spectrometry with electrospray ionization and multiple reaction monitoring interface and quantitatively determined by high performance liquid chromatography in an external standard manner. Results: The limits of detection (LOD) for avermectin and ivermectin were 2μg/kg and limits of quantitation were 5μg/L. Both the linear ranges of avermectin and ivermectin were 5-100μg/L with correlation coefficients of both 0.9999. The recovery rate range of this method was 77.0%-83.3% for avermectin and 76.9%-79.8% for ivermectin with relative standard deviations (RSD) of 8.6%-12.1% and 9.9%-13.0% at spike levels of 2, 10μg/kg and 20μg/kg, respectively. Conclusion: This method is simple, sensitive and accurate, which can meet the domestic and international requirements for the detection of both veterinary drugs.

Key words: pork liver, avermectin, ivermectin, high performance liquid chromatography-tandem mass spectrometry