食品科学 ›› 2024, Vol. 45 ›› Issue (6): 271-276.doi: 10.7506/spkx1002-6630-20230509-079

• 安全检测 • 上一篇    下一篇

基于衍生化3-氨基-2-恶唑烷酮的夹心酶联免疫分析

张世伟,吴会玲,周迎春,王炳志,杨星星,杜业刚,汤璐,冯荣虎,郭继平   

  1. (1.深圳市计量质量检测研究院,广东 深圳 518000;2.深圳市易瑞生物技术股份有限公司,广东 深圳 518000)
  • 出版日期:2024-03-25 发布日期:2024-04-03
  • 基金资助:
    深圳市科技计划项目(KCXFZ20230731092859013;JCYJ20210324141804012;JCYJ20210324141801003)

A Sandwich Immunosorbent Assay for 3-Amino-2-Oxazolidinone Following Derivatization

ZHANG Shiwei, WU Huiling, ZHOU Yingchun, WANG Bingzhi, YANG Xingxing, DU Yegang, TANG Lu, FENG Ronghu, GUO Jiping   

  1. (1. Shenzhen Academy of Metrology & Quality Inspection, Shenzhen 518000, China;2. Shenzhen Bioeasy Biotechnology Co. Ltd., Shenzhen 518000, China)
  • Online:2024-03-25 Published:2024-04-03

摘要: 建立一种3-氨基-2-恶唑烷酮(3-amino-2-oxazolidinone,AOZ)夹心免疫检测方法。通过1,6-己二醇连接2-硝基-4-羧基苯甲醛和生物素合成针对AOZ的新型衍生试剂。在样品前处理时加入衍生试剂可对AOZ进行衍生,衍生产率为89%。在酶标板上包被抗AOZ单克隆抗体并以辣根过氧化物酶标记的亲和素或抗生物素抗体作为第二结合物可实现AOZ的夹心酶联免疫吸附检测(enzyme-linked immunosorbnent assay,ELISA)。从实际应用的角度,得到双抗夹心和抗体-亲和素夹心模式下两个表位的极限距离,分别为12 Å和13 Å,理想距离分别为16 Å和17 Å。在双抗夹心和抗体-亲和素夹心模式下的检出限分别达到1.8 pg/mL和0.8 pg/mL(以AOZ质量浓度计),相对于竞争ELISA,其灵敏度最高提高了25 倍。平均回收率为73%~85%,平均相对标准偏差为9.0%。

关键词: 3-氨基-2-恶唑烷酮;夹心酶联免疫分析;表位间隔距离;辣根过氧化物酶标记亲和素

Abstract: In the present study, a sandwich enzyme-linked immunosorbent assay (ELISA) for 3-amino-2-oxazolidnone (AOZ) was developed. A novel derivatizing agent for AOZ was synthesized by linking 2-nitro-4-carboxybenzaldehyde and biotin through 1,6-hexanediol. During the sample pretreatment, the agent was added for AOZ derivatization with an efficiency of 89%. The monoclonal antibody (McAb) against AOZ was coated on the microplate and horseradish peroxidase-labeled avidin or anti-biotin antibody was used as a secondary conjugate in the ELISA method. From a practical perspective, the limit distances between the two epitopes in the double-antibody sandwich and antibody-avidin sandwich modes were 12 and 13 Å, respectively, and the ideal distances were 16 and 17 Å, respectively. The detection limits of the double-antibody sandwich and antibody-avidin sandwich modes were 1.8 and 0.8 pg/mL for AOZ, respectively. Compared with competitive ELISA, a 25-fold improvement in the sensitivity of the developed ELISA method was achieved. The average recoveries and average relative standard deviations (RSDs) were 73%–85% and 9.0%, respectively.

Key words: 3-amino-2-oxazolidinone; sandwich immunoassay; epitope spacing distance; horseradish peroxidase-labeled avidin

中图分类号: