FOOD SCIENCE ›› 2026, Vol. 47 ›› Issue (1): 301-308.doi: 10.7506/spkx1002-6630-20250728-216

• Safety Detection • Previous Articles    

Determination of Cholesterol Oxidation Products in Meat Products by Saponification at Room Temperature Combined with Gas Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry

LI Jie, CHEN Qianqian, WANG Yanli, TIAN Qiyan, LIANG Xiuqing, LI Xia, LI Xinling, LIU Yanming, SHEN Zhonglan   

  1. (Key Laboratory of Supervising Technology for Meat and Meat Products, State Administration for Market Regulation, Industrial Technology Foundation Public Service Platform, Shandong Institute for Food and Drug Control, Jinan 250101, China)
  • Published:2026-02-04

Abstract: In view of the diverse forms and unstable properties of cholesterol oxidation products (COPs) in meat products under specific conditions, a sample pretreatment technology, saponification at room temperature, was established for the accurate detection of 9 COPs in meat products by gas chromatography-quadrupole-time-of-flight mass spectrometry (GC-Q-TOF/MS). The results showed that the optimal pre-treatment conditions were extraction with chloroform/methanol (2:1, V/V), saponification at room temperature for 18 h, re-extraction with ethyl acetate/n-hexane (80:20, V/V), and clean-up using an aminopropyl solid-phase extraction (SPE) cartridge. The linear ranges were 0.002–0.5 μg/mL for 7α-hydroxyl cholesterol and 7β-hydroxyl cholesterol, and 0.02–0.5 μg/mL for 5β,6β-epoxide cholesterol, 5α,6α-epoxide cholesterol, 20α-hydroxy cholesterol, 3β,5α,6β-trihydroxy cholesterol, 25α-hydroxy cholesterol, 7-keto cholesterol and 27α-hydroxy cholesterol. The determination coefficients were ≥ 0.999 0 for all analytes, the limits of detection (LOQ) were 0.000 1–0.001 mg/kg, and the limits of quantitation (LOQ) were 0.000 2–0.002 mg/kg. The method had good accuracy and high precision. The average recoveries from spiked samples were 89.7%–116.1%, with relative standard deviations (RSDs) of less than 8.7%. Compared with high temperature saponification, saponification at room temperature effectively prevented the autoxidation of cholesterol and the degradation of 7-ketocholesterol, and reduced the exogenous introduction and endogenous loss of target substances, thereby enabling the rapid and accurate detection of the 9 COPs.

Key words: meat products; cholesterol oxidation products; saponification at room temperature; 7-keto cholesterol; gas chromatography-quadrupole-time-of-flight mass spectrometry

CLC Number: