FOOD SCIENCE ›› 2011, Vol. 32 ›› Issue (4): 185-188.doi: 10.7506/spkx1002-6630-201104040

• Analysis & Detection • Previous Articles     Next Articles

Determination of Avermectin and Ivermectin Residues in Pork Liver by High Performance Liquid Chromatography-Mass Spectrometry

ZHENG Wei-dong,HU Jiang-tao,YIN Wen-ya,SHENG Yi,WU Zhi-xiong   

  1. 1. Sichuan Institute of Product Quality Supervision and Inspection, Chengdu 610031, China; 2. Sichuan Entry-exit Inspection and Quarantine Bureau, Chengdu 610041, China; 3. Department of Nutrition and Food Hygiene, West China School of Public Health, Sichuan University, Chengdu 610041, China
  • Online:2011-03-12 Published:2017-04-06

Abstract: Objective: To establish a method for the simultaneous determination of avermectin and ivermectin residues in pork liver using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Methods: Avermectin and ivermectin residues were extracted with acetonitrile, cleaned up on a solid phase extraction (SPE) column containing alkaline aluminum oxide, separated on a C8 column, detected by tandem mass spectrometry with electrospray ionization and multiple reaction monitoring interface and quantitatively determined by high performance liquid chromatography in an external standard manner. Results: The limits of detection (LOD) for avermectin and ivermectin were 2μg/kg and limits of quantitation were 5μg/L. Both the linear ranges of avermectin and ivermectin were 5-100μg/L with correlation coefficients of both 0.9999. The recovery rate range of this method was 77.0%-83.3% for avermectin and 76.9%-79.8% for ivermectin with relative standard deviations (RSD) of 8.6%-12.1% and 9.9%-13.0% at spike levels of 2, 10μg/kg and 20μg/kg, respectively. Conclusion: This method is simple, sensitive and accurate, which can meet the domestic and international requirements for the detection of both veterinary drugs.

Key words: pork liver, avermectin, ivermectin, high performance liquid chromatography-tandem mass spectrometry

CLC Number: