Abstract:

建立液相色谱-质谱联用法测定白酒中8 种人工合成甜味剂的快速分析方法。液相色谱-质谱在负离子模式下,通过选择离子模式方式进行检测。8 种人工合成甜味剂在质量浓度0.04~2.0 mg/L范围内线性关系良好,相关系数为0.99,方法的定量限为0.04 mg/L,加标水平为0.1、0.5、1.0 mg/L和2.0 mg/L时,加标回收率为75.3%~109.3%,相对标准偏差为0.16%~8.85%。结果表明该方法简单、灵敏、准确,各项技术指标均满足国内外法规要求,可用于白酒中8 种人工合成甜味剂的检测。