  1. 1. Key Laboratory of Dairy Science, Ministry of Education, College of Food Science, Northeast Agricultural University, Harbin 150030, China; 2. Key Laboratory of Infant Formula Food, State Administration for Market Regulation, Harbin 150030, China; 3. Food Laboratory of Zhongyuan, Luohe 462300, China; 4. Key Laboratory of Cattle and Sheep Milk and Meat Products Risk Control and Key Technology, State Administration for Market Regulation, Harbin 150030, China; 5. National Engineering Research Center of Dairy Health for Maternal and Child, Beijing Engineering Research Center of Dairy, Beijing Technical Innovation Center of Human Milk Research, Beijing Sanyuan Foods Co. Ltd., Beijing 100163, China
  • Published:2026-11-06

Abstract: In this study, a fluorescent biosensing method for the rapid detection of Staphylococcus aureus in dairy products was developed by integrating molecular beacons (MB) as signal probes with polymerase chain reaction (PCR) and clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated protein 12a (CRISPR/Cas12a) technology. PCR primers were designed and screened based on the nuc gene of S. aureus. After optimization of the reaction systems and conditions, a standard curve was established, and the sensitivity and specificity of the developed method were evaluated. Finally, this method and real-time PCR were employed to detect S. aureus in samples to verify the accuracy of the proposed 收稿日期:2026-04-14 基金项目:国家自然科学基金青年科学基金项目(32402229); 黑龙江省省属本科高校“优秀青年教师基础研究支持计划”重点项目(YQJH2025020) 第一作者简介:曹明明(2000—)(ORCID: 0009-0002-5087-9378),女,硕士,研究方向为食品安全检测。 E-mail: 2421348466@qq.com *通信作者简介:陈历俊(1967—)(ORCID: 0000-0001-9055-8822),男,教授,博士,研究方向为食品质量与安全。 E-mail: chenlijun@sanyuan.com.cn 张现龙(1993—)(ORCID: 0000-0002-7773-0074),男,教授,博士,研究方向为食品质量与安全。 E-mail: zxl425618@163.com biosensor. The results demonstrated that the linear range for S. aureus detection was 102 to 108 CFU/mL (R2 = 0.996), with a limit of detection (LOD) of 1 CFU/mL and excellent specificity. Furthermore, the recoveries of this method for dairy samples spiked with different concentrations of S. aureus (104 , 105 , and 106 CFU/mL) ranged from 101.32% to 104.68%. These findings indicate that the proposed method possesses high sensitivity, specificity, and practical reliability, providing a valuable analytical approach for the field of dairy safety detection.

Key words: Staphylococcus aureus; molecular beacon; clustered regularly interspaced short palindromic repeats (CRISPR)/ CRISPR-associated protein 12a; fluorescence biosensor; dairy safety