FOOD SCIENCE ›› 2001, Vol. 22 ›› Issue (11): 76-78.
Previous Articles Next Articles
FU Ming, Chen-Xin-Huan, Yang-Wan-Biao, Yuan-Zhi-Neng, HU Yu-Dong
Online:
Published:
Abstract: Tea was digested by MDS- 2000 microwave clear up system,Arsenic,lead,Iron,Copper,Selenium all together 12 elements were determined. This paper study the method of dealing with the tea sample and determination conditions by ICP- AES,Influence such as acidity elements interferenence were discussed.The rate of recovery of the 12 elements is from 84.5% to 1.5% ,and the relation standard deviation (RSD)is less than 9.0% ,The results was satisfactory for tea.
Key words: Microwave clear up system ICP- AES Tea Arsenic Lead Iron Copper Selenium all together 12 elements
FU Ming, Chen-Xin-Huan, Yang-Wan-Biao, Yuan-Zhi-Neng, HU Yu-Dong. Determination of Arsenic,Lead,Iron,Copper,Selenium all Together 12 Elements in Tea by ICP-AES with Microwave Clear up System[J]. FOOD SCIENCE, 2001, 22(11): 76-78.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.spkx.net.cn/EN/
https://www.spkx.net.cn/EN/Y2001/V22/I11/76