FOOD SCIENCE ›› 2012, Vol. 33 ›› Issue (18): 258-260.

Previous Articles     Next Articles

Rapid Determination of Rhodamine B Residues in Fruit Drink by Fluorescent Probe Assay

  

  • Received:2012-05-20 Revised:2012-08-20 Online:2012-09-25 Published:2012-09-07

Abstract: A new fluorescence spectrometry method for the determination of rhodamine B (RhB) was established by the use of eosin Y (EY) as fluorescent probe. In Sфrensen buffer solution at pH 6.8, the fluorescence intensity of anionic dye EY can be significantly enhanced by adding cetyltrimethylammonium bromide (CTMAB), a cationic surfactant. However, RhB has the ability to quench the fluorescence in a proportional manner within a certain concentration range. In this study, one-factor-at-a-time designs were used to determine the optimal experimental conditions for the determination of RhB. The linear range, detection limit and average recovery rate of the developed assay were 0-0.9 mg/L, 0.0016 mg/L, and 101.3%-113.7% with relative standard deviation of 2.76%-4.98%, respectively. This method is simple, quick, selective and sensitive so that it is suitable for the determination of RhB residues in fruit drink products.

Key words: fluorescent probe, eosin Y, rhodamine B, residue

CLC Number: