食品科学 ›› 2021, Vol. 42 ›› Issue (1): 132-138.doi: 10.7506/spkx1002-6630-20200106-071

• 食品工程 • 上一篇    下一篇

低压静电场辅助冷藏对牛肉品质的影响

胡斐斐,钱书意,李侠,江峰,胡海梅,张春晖   

  1. (1.中国农业科学院农产品加工研究所,农业农村部农产品加工综合性重点实验室,北京 100193;2.长虹美菱股份有限公司,安徽 合肥 230000)
  • 发布日期:2021-01-18
  • 基金资助:
    国家自然科学基金面上项目(31671789)

Effect of Low Voltage Electrostatic Field-Assisted Chilling Storage on Quality of Beef

HU Feifei, QIAN Shuyi, LI Xia, JIANG Feng, HU Haimei, ZHANG Chunhui   

  1. (1. Comprehensive Key Laboratory of Agro-products Processing, Ministry of Agriculture and Rural Affairs, Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences, Beijing 100193, China; 2. Changhong Meiling Co. Ltd., Hefei 230000, China)
  • Published:2021-01-18

摘要: 为研究低压静电场辅助冷藏对牛肉品质的影响,采用牛背最长肌作为实验材料,探究其在静电场(实验组)和非静电场环境下(对照组)冷藏过程中的品质变化。对比分析了肉样在贮藏期间菌落总数、总挥发性盐基氮(total volatile basic nitrogen,TVB-N)含量、色泽、贮藏损失率、蒸煮损失率和剪切力的变化,并通过扫描电子显微镜、透射电子显微镜分别观察肌肉的微观结构和超微结构。结果表明:与静电板隔距10、30 cm和50 cm处肉样在贮藏第7天时菌落总数分别为5.11、5.54、5.27(lg(CFU/g)),显著低于对照组(6.41(lg(CFU/g)))(P<0.05)。贮藏期内,实验组肉样维持了较高的新鲜度,其TVB-N含量均显著低于对照组(P<0.05)。此外,贮藏期内与对照组相比,实验组肉样贮藏损失率更低,且剪切力显著下降(P<0.05),L*值、a*值显著升高(P<0.05),肉样的持水力、嫩度较高,色泽更亮。扫描电子显微镜、透射电子显微镜观察结果显示,实验组肉样贮藏期间肌纤维束排列相对紧密,较好地维持了肌肉微观结构。综上,低压静电场辅助冷藏可有效延长牛肉贮藏期,缓解其在贮藏期间的品质劣变,肉样与静电板的有效隔距为10~50 cm。

关键词: 低压静电场;牛背最长肌;品质;冷藏

Abstract: In order to study the effect of low voltage electrostatic field (LVEF)-assisted chilling storage on beef quality, changes in the total bacterial count, total volatile basic nitrogen (TVB-N) content, color, purge loss, cooking loss and shear force of bovine Longissimus dorsi muscles were determined during chilling storage with and without LVEF treatment. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to observe the microstructure of muscle tissues. On the 7th day of storage, the total bacterial counts of meat samples subjected to LVEF treatment at 10, 30 and 50 cm away from the electrostatic field generating plate were 5.11, 5.54 and 5.27 (lg(CFU/g)), respectively, which were significantly lower than 6.41 (lg(CFU/g)) observed for the control group (P < 0.05). Compared with the control group, the meat samples in the LVEF groups maintained higher freshness during the whole storage period and had significantly lower TVB-N contents (P < 0.05). Moreover, the meat samples in the LVEF groups exhibited significantly lower purge loss and shear force value (P < 0.05), significantly higher L* and a* values (P < 0.05), higher water-holding capacity and tenderness and a brighter color relative to the control group. SEM and TEM results revealed that the muscle fibers of LVEF-treated meat samples were more densely arranged and the microstructure was better maintained during storage when compared to the control group. In general, LVEF-assisted chilling could effectively prolong the shelf-life of beef and delay its quality deterioration and the effective distance between meat and electrostatic field generating plate was 10–50 cm.

Key words: low voltage electrostatic field; bovine Longissimus dorsi muscles; quality; chilling storage

中图分类号: