摘要: 建立基于气相色谱-串联质谱(gas chromatography-tandem mass spectrometry,GC-MS/MS)仪器,采用稳定性同位素稀释法测定猪肉中二噁英及二噁英类多氯联苯。样品经索氏提取,酸化硅胶除脂。然后经过多层硅胶柱、碱性氧化铝柱和活性炭柱净化,分别收集含二噁英(dioxins,PCDD/Fs)和二噁英类多氯联苯(dioxin like polychlorinated biphenyls,DL-PCBs)的组分。最后经浓缩溶剂交换后供GC-MS/MS测定。从样品的除脂方式、脂肪含量对净化的影响、系统空白污染来源等方面进行探讨。结果发现,凝胶渗透色谱除脂对PCDD/Fs和DL-PCBs的回收率影响较大,酸化硅胶除脂更适合超痕量的二噁英类化合物的分析和检测。二噁英检测的系统空白污染主要来自于索氏提取仪。该方法中内标的回收率为45.3%~122.4%,相对标准偏差(relative standard deviation,RSD)为1.0%~14.7%;目标物的回收率为64.9%~118.8%,RSD为1.1%~14.7%,方法线性和检出限能够达到GB 5009.205—2013《食品中二噁英及其类似物毒性当量的测定》的相关要求,适用于猪肉样品中PCDD/Fs和DL-PCBs的测定。

关键词: 气相色谱-串联质谱;二噁英;二噁英类多氯联苯;猪肉

Abstract: A gas chromatography-tandem mass spectrometry (GC-MS/MS) with stable isotope dilution (SID) method was established for the determination of dioxins (PCDD/Fs) and dioxin like polychlorinated biphenyls (DL-PCBs) in pork. The sample was extracted by Soxhlet extraction, defatted using acidified silica gel, and purified by sequential chromatography on a multi-layer silica gel column, an alkaline alumina column and an activated carbon column. PCDD/Fs- and DL-PCBs-rich fractions were collected separately, concentrated and redissolved for GC-MS/MS analysis. The influence of defatting method and fat content on the purification efficiency was investigated, and the blank contamination source of the system was discussed. The results showed that gel permeation chromatography (GPC) degreasing had a great influence on the recovery of PCDD/Fs and DL-PCBs, and acidified silica gel degreasing was more suitable for the analysis and detection of ultra-trace dioxins. The major blank pollution source of the dioxin detection system was the Soxhlet extractor. The recoveries for internal standard were 45.3%–122.4% with relative standard deviation (RSD) of 1.0%–14.7%. The recoveries for the analytes were 64.9%–118.8% with RSD of 1.1%–14.7%. Both the linearity and limit of detection (LOD) met the requirements of the national standard of China GB 5009.205-2013. The proposed method is suitable for the determination of PCDD/Fs and DL-PCBs in actual pork samples.

Key words: gas chromatography-tandem mass spectrometry; dioxins; dioxin-like polychlorinated biphenyls; pork