食品科学 ›› 2026, Vol. 47 ›› Issue (12): 365-372.doi: 10.7506/spkx1002-6630-20260109-078

• 安全检测 • 上一篇    

基于铁掺杂多孔碳纳米球的电化学传感器检测食品中的L-酪氨酸

黄青,诸葛文凤,凌晨东,张翠忠,彭金云,韦佳怡   

  1. (1.广西民族师范学院化学与材料学院,广西锰资源高值化利用重点实验室,广西 崇左 532200;2.广西华政新能源科技有限公司,广西 崇左 532200)
  • 发布日期:2026-07-08
  • 基金资助:
    广西民族师范学院学院科研创新团队项目(KYTD202405); 广西高校中青年教师科研基础能力提升基金项目(2024KY0784)

An Electrochemical Sensor Based on Iron-Doped Mesoporous Carbon Nanospheres for L-Tyrosine Detection in Foods

HUANG Qing, ZHUGE Wenfeng, LING Chendong, ZHANG Cuizhong, PENG Jinyun, WEI Jiayi   

  1. (1. Guangxi Key Laboratory for High-value Utilization of Manganese Resources, College of Chemistry and Materials, Guangxi Minzu Normal University, Chongzuo 532200, China; 2. Guangxi Huazheng New Energy Technology Co. Ltd., Chongzuo 532200, China)
  • Published:2026-07-08

摘要: 本研究通过配位辅助聚合组装法制备了铁掺杂多孔碳纳米球(mesoporous carbon nanosphere,MCN)复合材料,基于该复合物开发了一种具有高灵敏、高选择性的电化学传感新方法,用于检测L-酪氨酸(L-tyrosine,L-Tyr)含量。采用扫描电子显微镜、透射电子显微镜、X射线衍射等手段对材料的形貌、结构进行表征。将Fe-MCN修饰于玻碳电极(glassy carbon electrode,GCE)表面,构建了Fe-MCN/GCE电化学传感器,研究L-Tyr在Fe-MCN/GCE表面的电化学行为及动力学过程。在最优条件(pH 5.5)下,在L-Tyr浓度0.05~25 μmol/L范围内,氧化峰电流(Ip)与浓度(c)呈良好的线性关系:Ip=0.04c+0.013(R2=0.997 4),检出限为0.022 μmol/L。该传感器表现出优异的重复性、重现性和抗干扰能力,成功应用于实际L-Tyr营养增补剂、牛奶等样品检测,加标回收率在100.15%~104.00%之间。本研究可为食品中氨基酸的快速、灵敏检测提供一种性能优异的新型传感平台。

关键词: 铁掺杂;多孔碳纳米球;电化学传感器;L-酪氨酸

Abstract: In this study, a novel electrochemical sensing strategy with high sensitivity and selectivity was developed for the quantitative detection of L-tyrosine (L-Tyr). The iron-doped mesoporous carbon nanosphere (Fe-MCN) composite was successfully prepared via the coordination-assisted polymerization assembly method. The morphology and structure of the material were systematically characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray diffraction (XRD). The Fe-MCN composite was modified on the surface of a glassy carbon electrode (GCE), yielding a Fe-MCN/GCE electrochemical sensor. The electrochemical behavior and kinetic process of L-Tyr on the surface of Fe-MCN/GCE were investigated. Under the optimal conditions (pH 5.5), the oxidation peak current (Ip) showed a good linear relationship with L-Tyr concentration (c) within the range of 0.05–25 μmol/L: Ip = 0.04c + 0.013 (R2 = 0.997 4), and the detection limit (LOD) was 0.022 μmol/L. This sensor exhibited excellent repeatability, reproducibility, and interference resistance. It was successfully applied in the detection of L-Tyr in actual samples, including nutritional supplements and milk, with spiked recoveries ranging from 100.15% to 104.00%. This study provides a high‑performance sensing platform for the rapid and sensitive detection of amino acids in foods.

Key words: iron doping; mesoporous carbon nanospheres; electrochemical sensor; L-tyrosine

中图分类号: