食品科学 ›› 2023, Vol. 44 ›› Issue (12): 262-269.doi: 10.7506/spkx1002-6630-20220823-267

• 成分分析 • 上一篇    下一篇

不同品种葡萄中58 种挥发性物质的稳定同位素内标GC-MS SIM法分析

张雪枫,李杰,陈彦彤,何雪,陈文婷,杨国顺,谭君   

  1. (湖南农业大学园艺学院,湖南 长沙 410128)
  • 出版日期:2023-06-25 发布日期:2023-06-30
  • 基金资助:
    湖南省教育厅科学研究重点项目(19A243);国家自然科学基金面上项目(32172519); 国家现代农业产业技术体系建设专项(CARS-29-zp-9)

Analysis of 58 Volatile Components in Different Grape Varieties by Gas Chromatography-Mass Spectrometry with Selected Ion Monitoring Using Stable Isotope Labeled Internal Standard

ZHANG Xuefeng, LI Jie, CHEN Yantong, HE Xue, CHEN Wenting, YANG Guoshun, TAN Jun   

  1. (College of Horticulture, Hunan Agricultural University, Changsha 410128, China)
  • Online:2023-06-25 Published:2023-06-30

摘要: 在解析特殊挥发性物质的质谱裂解行为的基础上,建立气相色谱-质谱联用单离子监测(gas chromatography-mass spectrometry with selected ion monitoring,GC-MS SIM)稳定同位素内标法,对不同品种葡萄果实中的58 种挥发性物质进行精准的定性与定量分析,并探讨不同品种中挥发性物质的含量差异。葡萄果实样品破碎均质后,采用固相微萃取的方法进行高效富集萃取,再进行GC-MS SIM分析。结果表明,在特定的质量浓度范围内该方法线性关系良好,其线性相关系数在0.995 0(除异丙醇为0.967 1)以上;绝大多数目标物的检出限低于1.56 μg/kg;除个别挥发性物质的加标回收率较低,不同加标水平目标物样品回收率在60.64%~129.63%范围内,其回收率结果的相对标准偏差均低于19.56%。该方法具有灵敏度高、准确可靠的优点,适用于葡萄等水果蔬菜中挥发性物质的准确定性与定量研究。此外,本实验通过对12 个不同品种的葡萄果实样品中挥发性物质的差异分析,探明葡萄果实中的关键性挥发性物质,并挖掘出不同品种葡萄的特色挥发性物质。

关键词: 挥发性物质;葡萄;气相色谱-质谱;选择离子监测;稳定同位素内标物

Abstract: A gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM) method for the precise quantitative and qualitative analysis of 58 volatile components in grape fruits of different varieties using stable isotope labeled internal standard was developed based on the understanding of the mass spectrometric cleavage behavior of special volatile components. The difference in the volatile composition of the tested varieties was explored. After crushing and homogenization, grape samples were extracted by solid phase microextraction (SPME) and analyzed by GC-MS-SIM. The results indicated that this method had good linear relationships within the investigated concentration range with a correlation coefficient (R) greater than 0.995 0 for all analytes expect for isopropanol (equal to 0.967 1). The limits of detection (LODs) for most target compounds were lower than 1.56 μg/kg. The spiked recoveries of only a few volatile components were very low, while those of most volatile components ranged from 60.64% to 129.63% with relative standard deviations (RSDs) less than 19.56%. This method was suitable for qualitative and quantitative analysis of volatile components in grape and other fruits as well as vegetables, with high sensitivity and accuracy. Furthermore, the characteristic volatile components of 12 grape varieties were identified by analyzing the differences in their volatile composition.

Key words: volatile substances; grape; gas chromatography-mass spectrometry; selected ion monitoring; stable isotope labeled internal standard

中图分类号: