FOOD SCIENCE ›› 2009, Vol. 30 ›› Issue (12): 144-146.doi: 10.7506/spkx1002-6630-200912028

Previous Articles     Next Articles

Atomic Fluorescence Spectrometric Determination of Trace Selenium in Chinese Date

ZHANG Fu-wei,HOU Dong-yan,HUI Rui-hua   

  1. (Department of Chemistry, Anshan Normal University, Anshan 114007, China)
  • Received:2008-09-16 Revised:2009-01-08 Online:2009-06-15 Published:2010-12-29
  • Contact: ZHANG Fu-wei, E-mail:fuweizhang-2005@163.com

Abstract:

An atomic fluorescence spectrometric method was developed to determine trace selenium in Chinese date by taking 10% HCl solution as the current-carrying solution, selecting 2.0% potassium borohydride solution to enhance fluorescence intensity, and eliminating the disturbance of Pb2+, Cu2+ and Ag+ by enrichment with mercapto cotton and masking with thioureaascorbic acid. Results showed that the linear range and detection limit were 1.0-32.0 ng/ml and 0.57 ng/ml, respectively; the recovery varied from 99.0% to 106.3% and the RSD was lower than 1.71%.

Key words: Chinese date, selenium, atomic fluorescence spectrometry