FOOD SCIENCE

• Safety Detection • Previous Articles     Next Articles

Simultaneous Determination of 11 Functional Components in Health Foods by High Performance Liquid Chromatography

CHEN Yufang, LIN Haidan, WU Hongzhong, JIN Meng, SONG Yang, LIANG Xiaoru, XIE Yushan, GUAN Yongyi   

  1. Inspection and Quarantine Technology Center, Guangdong Entry-Exit Inspection and Quarantine Bureau, Guangzhou 510623, China
  • Online:2015-04-25 Published:2015-04-28

Abstract:

A high performance liquid chromatography (HPLC) method was developed for simultaneous determination
of 11 functional components in health foods. Samples were extracted with methanol-water-phosphoric acid solution/
n-hexane-methanol-water-phosphoric acid solution (for lipid-containing samples). Analysis was performed using an HPLC
system equipped with an Agilent TC- C18 column (250 mm × 4.6 mm, 5 μm) and a PDA/FLR detector with a mobile phase
composed of acetonitrile and 2 g/L sodium octanesulfonate solution (containing 1 mL of phosphoric acid) at a flow rate of
1.0 mL/min with gradient elution. Good linearity was observed in the range of 0.25–25 mg/L for vitamin B2, 0.5–20 mg/L
for vitamin B6, 1–100 mg/L for nicotinic acid and nicotinamide, 0.5–50 mg/L of the other five functional components with
correlation coefficients of 0.999 1–1.000 0. The average recoveries in health foods were in the range of 86.4%–110% at three
spiked levels with relative standard deviations varying between 0.21% and 11.7% (n = 6). The limit of quantification was
20 mg/kg for nicotinic acid and nicotinamide, and 10 mg/kg for the remaining nine functional components.

Key words: high performance liquid chromatography (HPLC), water-soluble vitamin, chromium picolinate, melatonine, salidroside

CLC Number: