食品科学 ›› 2011, Vol. 32 ›› Issue (22): 188-191.doi: 10.7506/spkx1002-6630-201122038

• 工艺技术 • 上一篇    下一篇

罗非鱼肉中土臭素和2-甲基异莰醇的测定

王国超1,2,李来好2,*,郝淑贤2,杨贤庆2,辛少平2,岑剑伟2,刁石强2,黄 卉2,魏 涯2   

  1. 1.中国海洋大学食品科学与工程学院 2.中国水产科学研究院南海水产研究所,国家水产品加工技术研发中心
  • 出版日期:2011-11-25 发布日期:2011-11-11
  • 基金资助:
    国家农业产业技术体系项目(CARS-49);国家农业科技成果转化项目(2010GB23260577;2009GB2E200303; 2010GB2E000335);广东省科技计划项目(2009A020700004;2008A020100006;2009B020201003);广东省海洋渔 业科技推广项目(A200899B02;A200901C01);农业部中央级公益性科研院所基本科研项目(2010YD07)

Determination of Geosmin and 2-Methylisoborneol in Tilapia Meat

WANG Guo-chao1,2,LI Lai-hao2,*,HAO Shu-xian2,YANG Xian-qing2,XIN Shao-ping2,CEN Jian-wei2, DIAO Shi-qiang2,HUANG Hui2,WEI Ya2   

  1. (1. College of Food Science and Engineering, Ocean University of China, Qingdao 266003, China; 2. National R&D Center For Aquatic Product Processing, South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China)
  • Online:2011-11-25 Published:2011-11-11

摘要: 通过微波蒸馏-固相微萃取-气相色谱-质谱方法测定罗非鱼肉中土腥味物质--土臭素和2-甲基异莰醇的含量。对微波蒸馏功率、微波蒸馏时间、载气气流等实验参数进行优化。结果表明:确立的最佳条件为微波功率360W(仪器额定功率的40%)、微波时间6min、载气流速60mL/min;在优化条件下,罗非鱼肉中的土腥味物质能最大限度地被检测出来,土臭素和2-甲基异莰醇的检测限分别达到了0.044μg/kg和0.095μg/kg,且它们在0.5~20μg/kg范围内呈较好的线性关系,r2分别达到了0.998和0.991,实验中土臭素和2-甲基异莰醇的回收率分别为42.7%、61.9%;最终利用该方法测得所购罗非鱼肉中土臭素和2-甲基异莰醇的含量分别为4.97、1.21μg/kg。

关键词: 土腥味物质, 微波蒸馏, 罗非鱼肉, 土臭素, 2-甲基异莰醇

Abstract: An analytical method was established for determining geosmin (GEO) and 2-methylisoborneol (MIB) as off-odor compounds in freshwater fish using gas chromatography-mass spectrum (GC-MS) based on microwave assisted distillation followed by solid phase microextraction. Such sample preparation parameters as microwave power, distillation time and carrier gas flow rate were optimized to be 360 W (40% of the maximum power), 6 min, and 60 mL/min, respectively. Under the optimized conditions, the detection limits were 0.044 μg/kg for GEO and 0.095 μg/kg for MIB. A good linearity was observed for GEO and MIB over the concentration range of 0.5 to 20 μg/kg with r2 of 0.998 and 0.991, respectively. The recoveries were 42.7% for GEO and 61.9% for MIB. Using this method, the contents of GEO and MIB in a commercially available tilapia meat sample were determined to be 4.97 μg/kg and 1.21 μg/kg, respectively.

Key words: off-flavor compounds, microwave-assisted distillation, tilapia, geosmin, 2-methylisoborneol

中图分类号: