食品科学 ›› 2013, Vol. 34 ›› Issue (23): 212-215.doi: 10.7506/spkx1002-6630-201323044

• 生物工程 • 上一篇    下一篇

纳米免疫磁珠富集单核增生李斯特菌的研究

钟子清,熊勇华,赖卫华*,许恒毅,山 珊,陈 奇,谢 芳,余扬帆   

  1. 南昌大学 食品科学与技术国家重点实验室,江西 南昌 330047
  • 收稿日期:2012-11-14 修回日期:2013-10-28 出版日期:2013-12-15 发布日期:2014-01-03
  • 通讯作者: 赖卫华 E-mail:talktolaiwh@163.com
  • 基金资助:

    “十二五”国家科技支撑计划项目(2011BAK10B01);国家自然科学基金项目(31271863)

Nanoparticle-based Immunomagnetic Separation of Listeria monocytogenes

ZHONG Zi-qing,XIONG Yong-hua,LAI Wei-hua*,XU Heng-yi,SHAN Shan,CHEN Qi,XIE Fang,YU Yang-fan   

  1. State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
  • Received:2012-11-14 Revised:2013-10-28 Online:2013-12-15 Published:2014-01-03
  • Contact: LAI Wei-hua E-mail:talktolaiwh@163.com

摘要:

比较抗体直接偶联、链霉亲和素-生物素介导偶联的免疫磁珠以及免疫磁珠的粒径对单增李斯特菌捕获效率的影响。结果表明:链霉亲和素-生物素介导偶联的免疫磁珠捕获效率约是直接偶联法的3倍;同时,磁珠粒径对捕获效率也有较大影响,当免疫磁珠用量为100μg时,180、350、1150nm的免疫磁珠捕获效率分别为95%、18%和9%。因此,采用链霉亲和素-生物素介导偶联的180nm免疫磁珠是一种低成本、易操作、高效率的单核增生李斯特菌富集方法。

关键词: 单核增生李斯特菌, 免疫磁分离, 链霉亲和素

Abstract:

The influence of antibody-coupling methods such as direct binding and streptavidin-biotin system on the
capture efficiency of immunomagnetic beads of different sizes (180, 350 nm and 1150 nm) for Listeria monocytogenes was
compared. The results showed that the capture efficiency of immunomagnetic beads using streptavidin-biotin method was
approximately two-fold higher than that of direct binding method. Meanwhile, the size of magnetic beads had significantly
effect on the capture efficiency. When the dosage of immunomagnetic beads was 100 μg, the capture efficiencies of
beads 180, 350 nm and 1150 nm in diameter were 95%, 18% and 9%, respectively, during the separation of Listeria
monocytogenes. Therefore, the 180-nm-diameter immunomagnetic beads prepared with streptavidin-biotin system can
provide a low-cost, easy-to- use and efficient method for rapid enrichment and detection of Listeria monocytogenes.

Key words: Listeria monocytogenes, immunomagnetic separation, streptavidin