食品科学

• 分析检测 • 上一篇    下一篇

微波消解-氢化物发生原子荧光光谱法测定婴儿配方乳粉中硒含量

卢 丽1,韦晓群1,刘二龙2,刘江晖1,覃小燕1,姚 红1,陈文锐1,*   

  1. 1.广东检验检疫技术中心,广东 广州 510623;2.黄埔出入境检验检疫局,广东 广州 510730
  • 出版日期:2014-10-25 发布日期:2014-11-07
  • 基金资助:

    广东省科技计划项目(2010A032000001)

Determination of Selenium in Infant formulas by Microwave Digestion-Hydride Generation Atomic Fluorescence Spectrometry

LU Li1, WEI Xiao-qun1, LIU Er-long2, LIU Jiang-hui1, QIN Xiao-yan1, YAO Hong1, CHEN Wen-rui1,*   

  1. 1. Guangdong Inspection and Quarantine Technology Center, Guangzhou 510623, China;
    2. Huangpu Entry-Exit Inspection and Quarantine Bureau, Guangzhou 510730, China
  • Online:2014-10-25 Published:2014-11-07

摘要:

建立微波消解-氢化物发生原子荧光光谱法测定婴儿配方乳粉中硒含量的方法。对还原剂、载流、预还原条件、铁氰化钾掩蔽效果、乳粉标准物质消解液及还原剂存放时间进行了研究。结果表明,在还原剂为1.0 g/100 mL KBH4-0.5 g/100 mL NaOH溶液,载流为8%盐酸,消解完全后的残留液中加5.0 mL 6 mol/L盐酸溶液后90 ℃加热至溶液体积约1 mL,不添加铁氰化钾做掩蔽剂,硒的线性回归方程为I=38.440 4C+1.362 7,线性范围为1.0~10 ng/mL,相关系数为1.000,方法检出限为0.084 ng/mL,加标回收率为90.4%~109%,相对标准偏差为2.9%(n=6)。乳粉标物消解液室温保存有效时间为3 d,还原剂避光冷藏保存有效时间至少1 周。本方法与国标法相比具有简便高效、节约试剂、更有利于操作人员身体健康和环境保护等优点,可以用来快速准确检测婴儿配方乳粉中硒含量。

关键词: 微波消解, 原子荧光, 婴儿配方乳粉,

Abstract:

A method for the determination of selenium in infant formulas was developed using microwave digestionhydride
generation atomic fluorescence spectrometry. Effects of reagents, pre-reducing methods, the presence or absence of
potassium ferricyanide, and reserving time of the sample digestion solution of certified reference material and the reducing
agent on the test results of selenium were studied. Under the appropriate reagent and pre-reducing condition, without using
potassium ferricyanide as masking agent, the linear regression equation was I = 38.440 4C+1.362 7 in the linear range
of 1.0–10 ng/mL (r = 1.000 0). The limit of detection (LOD) was 0.084 ng/mL, and the recovery rate of selenium from
spiked samples was 90.4%–109%, with relative standard deviation (RSD) of 2.9% (n = 6). The digestion solution of the
certified reference material GBW10017 (GSB-8 milk powder) could be stored at room temperature for three days before
determination and the reducing agent was valid within at least one week under refrigeration. The method was characterized
by simple operation, high efficiency, reagent-saving, easy operation and no pollution, and was suitable for rapid and accurate
determination of selenium in infant formulas.

Key words: microwave digestion, hydride generation atomic fluorescence, infant formula, selenium

中图分类号: