摘要:

建立超高效液相色谱-串联质谱(ultra performance liquid chromatography -tandem mass spectrometry,UPLCMS- MS)法检测饮料中的4-甲基咪唑(4-(5-)-methylimidazole,4-Mel)及2-甲基咪唑(2-methylimidazole,2-Mel) 的方法。以水溶解样品,OASIS®MCX固相萃取柱富集净化后,进入UPLC-MS-MS检测,内标法定量。在优化的条 件下,以ACQUITY UPLC® HILIC色谱柱(2.1 mm×100 mm,1.7 mm)为分析柱,乙腈和5 mmol/L甲酸铵溶液为 流动相,在电喷雾正离子多反应监测模式进行检测。结果表明,4-Mel和2-Mel在9~500 ng/mL范围内线性关系良 好。方法的定量限为3.0 mg/kg。在4 个加标水平下,3 种不同基质饮料中4-Mel和2-Mel的平均回收率分别为97.3% 和93.7%,相对标准偏差分别为3.8%和3.4%,该方法适用于饮料中4-Mel和2-Mel的检测。利用该方法对市售饮料中 4-Mel和2-Mel的含量进行检测,在软饮料、焦糖色饮料及咖啡饮料中检出含有4-Mel或2-Mel;而功能性饮料中未检 出4-Mel和2-Mel。

关键词: 超高效液相色谱-串联质谱, 4-甲基咪唑, 2-甲基咪唑, 固相萃取, 饮料

Abstract:

An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method was developed
for the determination of 4-(5-)-methylimidazole (4-Mel) and its isomer, 2-methylimidazole (2-Mel), in beverage. Samples
were diluted with water. An OASIS® MCX solid phase extraction column was used to purify and concentrate the target
analytes. Under the optimal conditions, the analytes were separated by a Waters ACQUITY UPLC® HILIC column (2.1 ×
100 mm, 1.7 mm) using a mobile phase consisting of acetonitrile and 5 mmol/L ammonium acetate aqueous solution. The
analytes were detected in multiple-reaction monitoring (MRM) mode via positive electrospray ionization (ESI+). The
results showed that the calibration curves of 4-Mel and 2-Mel were of good linearity in the range of 9–500 ng/mL. The
limit of quantification of the method was 3.0 mg/kg. The average recovery was 97.3% and 93.7% at four spiked levels (3.0,
25, 50 and 75 mg/kg) for 4-Mel and 2-Mel, respectively, and the relative standard deviation (RSD) was 3.8% and 3.4%,
respectively. These figures of merit indicated that the developed method can be used for the determination of 4-Mel and 2-Mel
in beverage samples. This method was applied to different beverages. 4-Mel or 2-Mel was found in soft drink, caramel
colored beverage and coffee. Contrarily, neither of them was found in energy drinks.

Key words: ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS), 4-(5-)-methylimidazole, 2-methylimidazole, solid phase extraction (SPE), beverage