FOOD SCIENCE ›› 2011, Vol. 32 ›› Issue (4): 223-226.doi: 10.7506/spkx1002-6630-201104050

• Analysis & Detection • Previous Articles     Next Articles

Evaluation of Measurement Uncertainty for the Determination of Potassium Permanganate Consumption of Food Contact Plastics

CAO Guo-zhou,YUAN Wei-wei,LI Lu,LIU Zai-mei,SUN Bin   

  1. Ningbo Entry-exit Inspection and Quarantine Bureau, Ningbo 315012, China
  • Online:2011-03-12 Published:2017-04-06

Abstract: In this study, factors affecting the determination of KMnO4 consumption of food contact plastics by the method of the Chinese National Standard GB/T 5009-2003 were analyzed, the main sources of measurement certainty were summarized, a procedure for certainty evaluation was established, and a relative standard uncertainty was obtained after calculating and synthesizing various uncertainty components and expanded. Potassium permanganate consumption was determined to be 2.26 mg/L for a polyethylene food box from a certain manufacturer, and the relative standard uncertainty for the determination was 0.039, and the expanded uncertainty was 0.176 mg/L (k = 2).

Key words: plastic articles, KMnO4 consumption, uncertainty

CLC Number: