摘要:

使用超声萃取- 反相高效液相色谱(HPLC)技术,建立同时分离和检测食物中苯甲酸、山梨酸、对羟基苯甲酸甲酯、对羟基苯甲酸乙酯、对羟基苯甲酸丙酯和对羟基苯甲酸丁酯6 种防腐剂的方法。水- 甲醇(5:95,V/V)作为提取溶剂进行超声萃取,采用Supelco Discovery C18 反相色谱柱,流动相为乙腈- 乙酸铵缓冲溶液(pH4.4)进行梯度洗脱,在1ml/min 的流速和254nm 的检测波长下14min 内6 种防腐剂得到良好分离。6 种防腐剂线性范围从5μg/ml 到100μg/ml,相关系数(r)为0.9997~1.0000。方法的平均回收率为90.1%~106.3%,精密度和稳定性的RSD分别为0.58%~1.79%、0.15%~1.65%,检出限的范围为0.012~0.43μg/ml。本方法的预处理过程简便、快速,应用于30 种进出口食品中防腐剂的分析检测,检测结果灵敏、可靠。

关键词: RP-HPLC, 超声萃取, 同时测定, 防腐剂, 食品

Abstract:

An ultrasonic extraction-reversed phased HPLC method was developed for the simultaneous separation and determination of 6 common preservatives such as benzoic acid, sorbic acid, methylparaben, ethyl P-hydroxybenzoate, nipasol and butyl P-hydroxybenzoate. Samples were extracted with the mixture of water and methanol (5:95, V/V) in ultrasonic field. The gradient elution was carried out on a Supelco Discovery C18 column, with an initial mobile phase of acetonitrile-acetate buffer (pH 4.4) and at the flow rate of 1.0 ml/min. The detector wavelength was set at 254 nm. Under these conditions, the separation of the 6 components was achieved within 14 min. The linear ranges for the determination 6 preservatives by this method were from 5 to 100 μg/ml with a correlation coefficient (r) of 0.9997-1.000, and the limits of detection were 0.012-0.43 μg/ml. The average recoveries for the 6 preservatives in sample spiked at three levels (10, 50 and 100 μg/g) were 90.1%-106.3% (n = 3). The RSDs of precision and stability were 0.58%- 1.79% (n = 5) and 0.15%- 1.65%, respectively. Finally, this method was applied to analysis of these preservatives in 30 different imported and exported food samples. Altogether, the pre-treatment procedure of the developed method is simple and rapid, and the result is sensitive and accurate.

Key words: RP-HPLC, ultrasonic extraction, simultaneous determination, preservative, foods